-40%

Altronix Proprietary Power Supply 24VDC 6.5 AMP NAC AL642ULADA New

$ 71.28

Availability: 100 in stock
  • Compatible Model: AL642ULADA
  • Item must be returned within: 30 Days
  • Refund will be given as: Money Back
  • Condition: New
  • Brand: Altronix
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • MPN: AL642ULADA

    Description

    WHAT YOU SEE IN THE PICTURES IS WHAT WILL BE SHIPPED TO YOUR DOOR!
    Altronix Proprietary Power Supply 24VDC 6.5 AMP NAC AL642ULADA New
    AL642ULADA are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories.
    Input
    Power input 120VAC 60 Hz, 4A.
    Two (2) Class A, Style Z or two (2) Class B, Style W, X, Y FACP inputs.
    Two (2) NC dry contact trigger inputs.
    Output
    Class 2 Rated power limited outputs.
    24VDC voltage regulated power limited outputs.
    6.5A max total alarm current.
    2.5A max current per output.
    Two auxiliary outputs rated at 1A each (1A continuous, 1A AC disconnect).
    Two (2) outputs may be paralleled for more power on an indicating circuit (see 42 Application Guide).
    Programmable supervised indicating circuit outputs:
    Four (4) Class B, Style W, X, Y or Four (4) Class A, Style Z or Two (2) Class A, Style Z and Two (2) Class B, Style W, X, Y (see 42 Application Guide).
    Thermal and short circuit protection with auto reset.
    Battery Backup
    Charging voltage is 26.2-26.4VDC.
    Built-in charger for sealed lead acid or gel type batteries.
    Automatic switchover to stand-by battery when AC fails.
    Zero voltage drop when switching over to battery backup.
    Supervision
    AC fail supervision (form "C" contact, 1A/28VDC). Factory set for 30 seconds with optional 2.5 to 3 hour delay setting (field selectable).
    Instant local AC trouble reporting relay (form "C" contact, 1A/28VDC).
    Battery presence and low battery supervision (form "C" contact, 1A/28VDC).
    Visual Indicators
    Input and output status LED indicators.
    Special Features
    2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
    Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
    Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
    Compatible with 24VDC fire panels.
    Output loop supervision directed to input 1 or input 2.
    Signal Circuit Trouble Memory - facilitates quick identification of an intermittent/fault (short circuit, open or ground) which has previously occurred on one or more signaling circuit outputs. LEDs indicate/identify which output the fault has occurred.
    Common trouble input and output for external trouble signals tie-in.
    Ground fault detection.
    Unit includes power supply, logic board enclosure, cam lock, and battery leads.
    Temperature
    Operating 0° C to 49° C (32° F to 120° F).
    Storage - 20° C to 70°C ( - 4° F to 158° F).
    Relative Humidity 85% +/- 5%.
    BTU/Hr (approx.): 31 BTU/Hr. sa- 31